Developpement´ d’une approche hybride pour l’amelioration´ des images CBCT pour la radiotherapie´ adaptative
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Université Sétif 1 - Ferhat ABBAS , Faculté de Technologie
Abstract
Recently, the integration of in-board cone beam computed tomography ( CBCT ) systems into linear accelerators has provided not only a powerful tool for improving the accuracy of patient positioning but also it makes it possible to adapt the treatment planning with the patient anatomy modifications throughout the entire treatment, known as adaptive radiation therapy (ART). During ART planning, after applying a rigid registration between daily acquired CBCT images and planning CT ( pCT ) scans and getting information about patients structural changes and internal organs deformations, a repeated acquisition of CT images (repCT) is needed for replanning if the patients anatomical changes are significative. Although repCT images provide the most up-to-date information for a human body with an accurate hounsfield unit (HU) distribution for dose calculation, their repeated acquisition may pose a health concern to patients due to the additional dose. Therefore, the aim of this thesis is to investigate the feasibility of daily CBCT images for dose calculation instead of acquiring repCT images. The main interest is to propose a promising strategy to overcome the limitations related to the high amount of scatter that reduces the quality of CBCT images compared to the pCT.
To this end, we proposed three complementary approaches that allow the correction of the HU distribution in the CBCT images. The first proposed approach is inspired from the fact that the CBCT and the pCT images have not the same gray-level histograms. Therefore, we applied the histogram matching (HM) process to resemble their histograms and offer the possibility to distinguish the different tissue types in the CBCT images. As a second approach, we proposed the application of multilevel threshold (MLT) to improve the correctness of the HU distribution obtained with HM. Finally, in the third approach we proposed the generalization of the previously proposed approaches to contribute in the minimization of the ART workload requirements. The main idea is to include the notion of inter-patient deformable registration in order to investigate the pCT images available in the archive for the correction of CBCT images rather than acquiring new CT images for each patient.
Results of the visual and statistical analysis showed that the proposed approaches ABSTRACT
can improve the HU distribution in the CBCT images and generate corrected images in good agreement with the pCT.