Traitement des eaux de forage par osmose inverse au niveau de la base de vie IRARA de la société SONATRACH OUARGLA
Loading...
Files
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Université Sétif1 Ferhat Abbas. Faculté des Sciences
Abstract
The present work studied the efficiency of the borehole water treatment unit intended for consumption, using the reverse osmosis technique at Sonatrach Irrara living base in Hassi Messaoud. The study mainly focused on monitoring the temporal and spatial variation of conductivity to evaluate its effectiveness. This method is used to remove dissolved salts and impurities from raw water. The analysis of conductivity variation was conducted at different points of the unit: from the well water, osmotically treated water (at the membrane outlet), and the final treated water.
The results show that the conductivity of the raw water from the well averages 4323.3 µS/cm, whereas, at the reverse osmosis membrane outlet, it significantly decreases to 128.2 µS/cm. After the remediation and final treatment process, the conductivity of the water reaches an average of 951.85 µS/cm, which remains within potable water standards. The reverse osmosis conductivity reduction efficiency is 97.03%, while the total conductivity reduction efficiency is 77.98%. These results demonstrate the effectiveness of the reverse osmosis process in reducing impurities and mineralizing the water, ensuring optimal quality drinking water.