Abstract
The quality control of antiseptic preparations is essential to ensure the safety and effectiveness
of products intended to eliminate or inhibit microorganisms on the skin and mucous
membranes. It involves a series of physicochemical and microbiological tests designed to verify
compliance with regulatory standards and to guarantee optimal antiseptic activity during
healthcare procedures. The present study aimed to evaluate the quality and regulatory
compliance of two commonly used antiseptics, namely iodinated alcohol and hydrogen
peroxide, obtained from different pharmaceutical laboratories.
For iodinated alcohol, samples E1, E3, and E4 failed to comply with the density specifications
established by the National Formulary (2007). The acidity test indicated that sample E3 was
compliant, reflecting satisfactory chemical stability and appropriate preparation and storage
conditions. However, all analyzed samples were found to be non-compliant with the iodine
assay, exhibiting significantly lower iodine concentrations than required. This deficiency may
be attributed to the volatilization of molecular iodine during storage.
Regarding hydrogen peroxide, all tested samples complied with Identification Test A,
confirming the presence of hydrogen peroxide and indicating that the concentration of reducing
substances remained within the limits specified by the pharmacopoeial monograph. In contrast,
sample E3 did not meet the requirements of Identification Test B. The acidity test revealed that
samples E2, E3, and E5 complied with the established standards, whereas samples E1 and E4
showed non-compliance, likely due to the presence of excessive acidic impurities.
The determination of hydrogen peroxide content by manganimetric titration demonstrated that
none of the analyzed samples reached the required concentration, indicating non-compliance
with quality specifications. This result can be mainly explained by the intrinsic instability of
hydrogen peroxide, a compound highly sensitive to environmental factors such as light and
heat.
In conclusion, quality control of antiseptic preparations constitutes a crucial component of
healthcare safety and infection prevention. It ensures that antiseptic products possess adequate
antimicrobial activity while maintaining their safety for use on living tissues